CARTO® Software



CARTO VISITAG™


CARTO VISITAG™
Module with Ablation Index

By providing a built-in algorithm and standard workflow, the CARTO VISITAG™ Module with Ablation Index allows EPs to focus on a single value – the Ablation Index – which represents stability, power, contact force, and time. With Ablation Index, EPs can reproduce their own successful ablation strategy in a standard and simple way by eliminating variability and improving accuracy.



Features & Benefits:

  • Seamless integration with CARTO VISITAG Module tag visualization
  • Supported by scientific data, treating patients is more consistent
  • EPs can manage a single number rather than having to focus on multiple data points
  • Objective tag placement based on customized settings
  • A single center study resulted in >90% single procedure success rate at 1 year follow-upi





CARTO CONFIDENSE™ Module with Ripple Mapping

Ripple Mapping seamlessly integrates with the CARTO® CONFIDENSE Module capabilities and voltage mapping to provide a dynamic display of bipolar electrogram data in an electroanatomical map.
Ripple Mapping is designed to help you better understand the arrhythmia mechanism by displaying a global view while highlighting areas of interest.



Features & Benefits:

Features & Benefits:

  • Unique visual representation of bipolar voltage provides a holistic view assisting in identification of multi-component signals and associated activation patterns.

Ripple Mapping is not dependent on local annotation or Window of Interest settings. This may simplify set-up steps and allows for visualization of activation across the arrhythmia cycle length






CARTOSEG CT Segmentation Module

The CARTOSEG™ CT Segmentation Module automates the CT segmentation process, providing detailed anatomic 3D image integration in the CARTO® 3 System while highlighting discrete anatomic structures.
This module semi-automatically segments all four chambers, aorta, coronary sinus, coronary arteries and esophagus.


Features & Benefits:

Features & Benefits:

The CARTOSEG™ CT Segmentation Module provides anatomic detail to enable you to efficiently plan your ablation strategy when treating complex arrhythmias.




CONFIDENSE™


CARTO®
CONFIDENSE™
Module

The CONFIDENSE™ Mapping Module offers CARTO® 3 System users a complete and streamlined high-density mapping solution. By refining the MEM experience, the CONFIDENSE™ Module introduces a new degree of control over point acquisition and insight into your mapping procedures. This high-performance mapping is fully integrated into the CARTO® System.


Features & Benefits:

  • Continuous Mapping: Automated data acquisition (when physician set-criteria are met)
  • Tissue Proximity Indication: Proximity-based filtering of points acquired with MEM catheters
  • Wavefront Annotation: An automated annotation algorithm that incorporates both unipolar and bipolar signals
  • Map Consistency: System identifies outlying points when certain criteria are met



PASO™ Module



CONFIDENSE™
with Pattern Matching

Pattern Matching is a continuous mapping filter that enables CARTO® 3 System users to selectively acquire beats that represent a particular ventricular rhythm when using the CARTO® CONFIDENSE™ Module. When combined with the PENTARAY® Catheter, the CARTO® CONFIDENSE™ Module with Pattern Matching allows users to efficiently map and determine the mechanism of complex ventricular arrhythmias.i


Features & Benefits:

  • 12-lead Body Surface ECG as a reference
  • Points are acquired only when a beat matches the user defined pattern within the correlation threshold
  • 12x more efficient than point-by-point mapping with THERMOCOOL SMARTTOUCH® Catheteri
  • Filters out 99.7% of the beats unrelated to the mapped rhythm with 98% sensitivity at a 0.9 correlation value settingii



paso


®
PASO™
Module

The PASO™ Module delivers automated template matching for targeting complex ventricular tachycardia procedures. It automatically compares pace mapping signals with arrhythmia signals to better inform your VT ablation strategy.


Features & Benefits:

  • Locate VT sources
  • Customize preferences
  • Instantly compare pace mapping and arrhythmia signals
  • Track multiple VT morphologies automatically



CARTO SMARTTOUCH™


CARTO SMARTTOUCH™
Module

Add a new dimension of certainty with the knowledge that comes from seeing RF ablation parameters displayed in real time on a single screen. The CARTO SMARTTOUCH™ Module allows active measurement of stable contact force and catheter tip direction. Seamless integration with the CARTO® 3 System incorporates CARTO VISITAG™ Module technology to display key ablation variables related to lesion formation.



Features & Benefits:

  • Helps to visualize and maintain catheter stability within a user-selected range
  • User-defined parameters for distance moved (measures in millimeters) over a selected time permit stability requirement to be adjusted
  • Observe force and catheter orientation
  • Vector arrows show actual angle of catheter tip to tissue
  • Color-coded catheter tip indicates progress to target force value
  • Force graph displays accurate force in window and CARTO VISITAG Module information grid


Arya Hakim Logo





Arya Hakim Logo




Phone:(+98) 21 665 922 72 – 82
Fax: (+98) 21 66 90 72 70
Email: info@aryahakim.com

No.294, West Fatemi, Tehran, Iran


By Mutrana . All rights reserved.



By Mutrana . All rights reserved.