Navigational Therapeutic Catheters




CARTO® THERMOCOOL SMARTTOUCH® SF

Combining THERMOCOOL SMARTTOUCH® Technology with SF Catheter Porous Tip. This catheter combines effectiveness of contact force sensing with advanced irrigated porous tip ablation, and adds enhanced handling and torque for excellent control. Integrated into CARTO SMARTTOUCH® Software Module for additional ablation monitoring.


Features & Benefits:

Features & Benefits:

  • Uniform cooling at half the flow rate
  • Enhanced maneuverability and handling





CARTO® THERMOCOOL SMARTTOUCH®
(Bi-Directional Catheter)

Deliver a new measure of success to your cardiac arrhythmia patients with the THERMOCOOL SMARTTOUCH® Catheter. Greater catheter stability results in more consistent contact force, producing more uniform lesions. The SMART-AF Trial evaluated the safety and effectiveness of the THERMOCOOL SMARTTOUCH® Catheter in patients with drug-resistant paroxysmal atrial fibrillation. One-year results from the trial showed patients experienced an overall success rate of 74 percent. Importantly, a sub-analysis from the trial demonstrated an 88 percent success rate when contact force was within an investigator–selected range greater than or equal to 85 percent of time.


Features & Benefits:

Features & Benefits:

  • Force-sensing technology that provides real-time measurement of contact force between the catheter tip and the heart wall
  • Tip electrode serves to deliver RF current from the RF generator to the desired ablation site
  • A thermocouple temperature sensor is embedded in the tip electrode
  • High-torque shaft with a bi-directional deflectable tip section containing an array of electrodes





CARTO® THERMOCOOL® SF

Advance open irrigation to a new level with the THERMOCOOL® SF Catheter. Innovative catheter design allows for uniform cooling across the entire catheter tip at half the flow rate. The advanced porous tip design enables maximum cooling efficiency regardless of catheter orientation, helping to further reduce the risk of thrombus formation. Irrigated catheters help to further reduce the risk of thrombus formation.


Features & Benefits:

Features & Benefits:

  • Easier fluid management due to half the flowrate
  • 3.5mm tip – with no trade-offs between power and signal resolution
  • Curve visualization





CARTO® THERMOCOOL®
(Bi-Directional Catheter)

Open irrigation overcomes the limitations of non-irrigated ablation by lowering electrode and tissue surface temperature, bringing together the efficacy of power delivery with the safety of reduced char formation.1 Bi-directional access helps reaching desirable anatomical area.


Features & Benefits:

Features & Benefits:

  • Remarkable catheter handling and tip-to-tissue contact
  • Two curves in one catheter





CARTO® NAVISTAR®

NAVISTAR® Catheter is a steerable, multiple electrode catheter with a deflectable tip to facilitate electrophysiological mapping of the heart and to transmit RF (radiofrequency) current to the catheter tip electrode for ablation purposes. For mapping, the catheter is used with the CARTO® 3 System, and an appropriate location reference device. For ablation, the catheter is used in conjunction with a compatible RF generator and grounding (dispersive) pad.


Features & Benefits:

Features & Benefits:

  • High-torque polyurethane shaft with a deflectable tip section that includes an array of platinum electrodes
  • All electrodes may be used for recording and stimulation, but only the tip electrode may be used to deliver RF energy from the generator
  • Magnetic location sensor embedded in the tip electrode that transmits location information to the CARTO® 3 System


Arya Hakim Logo





Arya Hakim Logo




Phone:(+98) 21 665 922 72 – 82
Fax: (+98) 21 66 90 72 70
Email: info@aryahakim.com

No.294, West Fatemi, Tehran, Iran


By Mutrana . All rights reserved.



By Mutrana . All rights reserved.